Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Circ Rep ; 5(11): 415-423, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37969232

RESUMEN

Background: There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation. Methods and Results: In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient's home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1-1] vs. 5 [3-5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64-117] vs. 24 [0.1-24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits. Conclusions: A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.

2.
J Cardiovasc Electrophysiol ; 34(7): 1569-1576, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37313805

RESUMEN

INTRODUCTION: Intermuscular implantations of subcutaneous implantable cardioverter-defibrillators (S-ICD) have been recommended, but the position of the anterior border of the latissimus dorsi muscle (LDM) has not previously been evaluated in establishing an incision line to facilitate the intermuscular approach. The objective of this study is to evalua the position and trend of the anterior border of the LDM in patients who are candidates for implantable cardioverter-defibrillators. METHODS: The distance from the back to the anterior border of the LDM (A) and the anterior-posterior width of the chest wall (B) were measured on computed tomography retrospectively, and the ratio (=A/B) was used as the position of the anterior border of the LDM. In addition, the variability and factors affecting the values were evaluated. RESULTS: An analysis was performed on 78 patients, and the position of the anterior border of the LDM (=A/B) exhibited a normal distribution, with a mean value of 0.53 ± 0.062 (0.41-0.69). The position of the anterior border of the LDM tended to be more anterior in younger, taller, male, primary prevention, nonheart failure, low brain natriuretic peptide level, and nondiabetic patients. CONCLUSION: The position of the anterior border of the LDM varied from case to case with variable results. Conventional incisions on the midaxillary line may be inappropriate for intermuscular implantations, and the position of the anterior border of the LDM should be evaluated in each individual case to establish the incision line.


Asunto(s)
Desfibriladores Implantables , Músculos Superficiales de la Espalda , Herida Quirúrgica , Humanos , Masculino , Músculos Superficiales de la Espalda/diagnóstico por imagen , Músculos Superficiales de la Espalda/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos
3.
J Cardiovasc Electrophysiol ; 34(3): 527-535, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36598438

RESUMEN

BACKGROUND: Lesion gaps assessed by late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) are associated with the atrial fibrillation (AF) recurrence after pulmonary vein isolation. Animal studies have demonstrated that the catheter-contact force (CF), stability, and orientation are strongly associated with lesion formation. However, the impact of those procedural factors on the lesion characteristics associated with AF recurrence has not been well discussed. METHODS: A total of 30 patients with paroxysmal AF who underwent catheter ablation were retrospectively enrolled. Radiofrequency (RF) applications were performed with 35 W for 30 s in a point-by-point fashion under esophageal temperature monitoring. The inter-lesion distance was 4 mm. The lesions were visualized by LGE-MRI 3 months postprocedure and assessed by the LGE volume (ml), gap number (GN), and average gap length (AGL [mm]). The gaps were defined as nonenhancement sites of >4 mm. The procedural factors including the catheter-CF, stability, and orientation were calculated on the NavX system. RESULTS: Six (20%) of 30 patients had AF recurrences 12 months postablation. A univariate analysis demonstrated that the AGL was associated with AF recurrence (hazard ratio [HR]: 1.20, confidence interval [CI]: 1.03-1.42, p = .02). All AF recurrence were found in patients with an AGL of >7 mm. The catheter-CF and stability were associated with an AGL of >7 mm, but not the orientation (CF-HR: 0.62, CI: 0.39-0.97, p = .038; stability-HR: 0.8, CI: 0.66-0.98, p = .027). CONCLUSIONS: RF ablation with a low CF and poor catheter stability has a potential risk of creating large lesion gaps associated with AF recurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Medios de Contraste , Gadolinio , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Ablación por Catéter/métodos , Recurrencia , Venas Pulmonares/cirugía , Atrios Cardíacos , Resultado del Tratamiento
4.
J Arrhythm ; 38(6): 1056-1062, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36524047

RESUMEN

Background: It is uncertain whether cardiac resynchronization therapy with a defibrillator (CRT-D) provides better survival benefits than a CRT-pacemaker (CRT-P) in heart failure patients with a reduced ejection fraction (≦35%, HFrEF) treated with contemporary HF therapy. Methods: We retrospectively analyzed the ventricular arrhythmia (VAs; sustained ventricular tachycardia/fibrillation) events in HFrEF patients who underwent CRT without a prior history of VAs or aborted sudden cardiac death before the CRT implantation. Between January/2010 and December/2020, a CRT device was implanted in 79 HFrEF patients (mean age: 69 ± 12 years, male: 57, ischemic cardiomyopathy: 16). CRT-D and CRT-P devices were implanted in 50 and 29 patients, respectively, at each physician's discretion. CRT-Ds were indicated in younger patients than were CRT-Ps (66 ± 12 vs. 73 ± 12 years, p = 0.03), but the gender distribution did not differ (female, 24% [12 of 50] vs. 35% [10 of 29], p = 0.44). The VA events during a median follow-up of 3.5-years (interquartile range [IQR]:1.6-5.5) and their predictors were analyzed. Results: VA events occurred in 9 patients with CRT-Ds (18%) and one with a CRT-P (3%, p = 0.08). The VA event rate was significantly lower in patients without a prior non-sustained ventricular tachycardia (NSVT: ≥3 beats; rate, ≥120 bpm; lasting <30 s, HR 0.05; 95% CI 0.01-0.30; p < 0.01) and females (HR 0.11; 95% CI 0.01-0.93; p = 0.04). Of note, no female patients without a prior history of NSVT experienced VA events. Conclusion: HFrEF CRT candidates without a prior history of NSVT and females may obtain less benefit from a primary preventive defibrillator indication.

5.
Nihon Shokakibyo Gakkai Zasshi ; 116(7): 607-616, 2019.
Artículo en Japonés | MEDLINE | ID: mdl-31292323

RESUMEN

Cirrhotic cardiomyopathy (CCM) is a chronic cardiac dysfunction in patients with cirrhosis and is characterized by altered diastolic relaxation, blunted contractile response to stress, and electrophysiological abnormalities;however, causes of CCM are unknown. Moreover, reduced cardiac afterload due to cirrhosis-related vasodilatation often masks cardiac insufficiency, whereas rapid hemodynamic overload reveals the presence of cirrhotic cardiomyopathy. Herein, we present the case of previously unrecognized cirrhotic cardiomyopathy that became overt with the development of severe acute cardiac failure. The rapidly worsening hepatic hydrothorax increased cardiac preload and intrathoracic pressure, which impaired cardiac filling. Furthermore, cardiac contractile function might have been worsened by hypoxia due to passive atelectasis and concomitant anemia.


Asunto(s)
Cardiomiopatías/diagnóstico , Insuficiencia Cardíaca/diagnóstico , Hidrotórax/diagnóstico , Cirrosis Hepática Alcohólica/diagnóstico , Cirrosis Hepática , Cardiomiopatías/complicaciones , Insuficiencia Cardíaca/complicaciones , Humanos , Hidrotórax/complicaciones , Cirrosis Hepática Alcohólica/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...